Intsall new PLC,run new multi communication cables for different junction boxes for waste wood products at Boiler house for Masonite Africa limited during shutdown . Remove DC Drives (VSD) and rewire and install AC Drives(VSD) for table rollers for production plant during shutdown
Prior to hygiene regulations, Attend to breakdowns Fault finding in PLC's,AC Drives,D.O.LWorked on high speed packing machines,cooking machines and videojet printers,calibrate clover scales Assisted in refrigeration plant MCC(repaired,inspected,fitted,circuits,wiring systems&electrical equipment.)
Workshop Assistant Mechanical Workshop (Grinding plates for cozzini grinder & cozzini emulsifier machines.seydelmann machine,mincer machine for Ham Dep.) Assist with maintenance Electrical Workshop (Prior to hygiene regulations,Assist in breakdowns,fault finding in PLC's,AC drives,D.O,L ,high speed packing machine multivac,handtman & frey fillers & tipper tie alpina clippers,video jet printers(1220 &1210),calibrate clover scales(Kilograms&Grams) & Pt100 probe
Monitor -10 and -35 compressor Change oil on compressor Change faulty fans inside cold rooms and freezers Make sure all the cold rooms,chillers and the freezers are working well for production Check condensers for discharge liquid Check oil coolers for better performance of the compressors
Electrician trade test
N4-N6 national diploma